Description
MILWAUKEE-MA-888

Range | “0 to 100% Volume Freezing Point 0 to -50°C (32 to -58°F) Temperature 0 to 80°C / 32 to 176°F” |
Resolution | “0.1% Volume Freezing Point 0.1°C (0.1°F) Temperature 0.1°C / 0.1°F” |
Accuracy | “±0.2% Volume Freezing Point ±0.5°C (±1°F) Temperature ±0.3°C / ±0.5°F” |
Light Source | Yellow LED |
Measurement Time | Approximately 1.5 seconds |
Minimum Sample Volume | 100 µL or 2 metrics drops (cover prism totally) |
Sample Cell | Stainless steel ring and flint glass prism |
Temperature Compensation | Automatic between 0 and 40°C / 32 to 104°F |
Enclosure Rating | IP65 |
Case Material | ABS |
Order Code | MA-888 |
The Milwaukee digital Ethylene and Glycol refractometer is temperature compensated with a 0 to 100 % volume / 0 to -50°C (32 to -58°F) freezing point / Temperature 0 to 80°C (32 to 176°F) range and +/- 0.2 volume / +/-0.5°C (+/-1°F) freezing point accuracy. It is easy to use with simple two button operation and fast with a response time under 2 seconds. Maintenance is a breeze also with an easy-to-clean sealed flint glass prism and stainless steel well. The MA888 eliminates the uncertainty of optical refractometers by providing and accurate digital readout.
FEATURES
- Fast, accurate results with digital dual level LCD readout.
- Easy measurement with just 2-3 drops of sample needed and results less than 2 seconds.
- Simple one-point calibration using distilled or deionized water.
- Easy to clean, stainless steel sample well with unit rated to IP65 as “dust tight” and protected against water jets.
- Battery percent level indicator with automatic shut-off (batteries included).
- Ideal for winemakers, brewers, syrup producers, food producers and many other applications.
- The instrument utilizes internationally recognized references for unit conversion and temperature compensation for ethylene glycol.
SPECIFICATIONS
- Range: 0 to 100% Volume | Freezing Point 0 to -50°C (32 to -58°F) | Temperature 0 to 80°C / 32 to 176°F
- Resolution: 0.1% Volume | Freezing Point 0.1°C (0.1°F) | Temperature 0.1°C / 0.1°F
- Accuracy: ±0.2% Volume | Freezing Point ±0.5°C (±1°F) | Temperature ±0.3°C / ±0.5°F
- Light Source: Yellow LED
- Measurement Time: Approximately 1.5 seconds
- Minimum Sample: Volume 100 µL or 2 metrics drops (cover prism totally)
- Sample Cell: Stainless steel ring and flint glass prism
- Temperature Compensation: Automatic between 0 and 40°C / 32 to 104°F
- Enclosure rating: IP65
- Case Material: ABS


There are no reviews yet.